OUR SPEEDRES PREFAB MOBILE RESIDENTIAL ACCOMODATION (PARKHOME) OFFERS ALL THE USUAL HOUSE COMFORTS ON SITE, NO MATTER WHERE YOU ARE
Ufudu offers you Speedres, comfortable, welcoming ‘home from home’ prefabricated mobile residential accommodation (Parkhomes), designed for singles or families on site. These temporary mobile houses provide a high standard of finishings and fittings, in no way inferior to those of many more permanent houses.
These fully-insulated, portable, prefab residential accommodation units (Parkhomes) include all house comforts, uncramped living space on site, and appliances to order.
Once the occupants start planting flowerbeds outside these mobile Parkhomes, you’ll know they feel at home on site!
SPEEDOFFICE SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Description | Model | Model | Model | Model | Model | Model |
S6241 | 6301 | S96301 | S12301 | S15341 | S18341 | |
Length (ext) | 5 820 | 5 820 | 9 300 | 11 620 | 15 100 | 17 420 |
Length (int) | 5 740 | 5 740 | 9 220 | 11 540 | 15 020 | 17 340 |
Width (ext) | 2 420 | 2 990 | 2 990 | 2 990 | 3 580 | 3 580 |
Width (int) | 2 260 | 2 910 | 2 910 | 2 910 | 3 500 | 3 500 |
Height (int) | 2 400 | 2 400 | 2 400 | 2 400 | 2 400 | 2 400 |
Electrics | Standard | Standard | Standard | Standard | Standard | Standard |
Aluminium Windows | Standard | Standard | Standard | Standard | Standard | Standard |
Vinyl Floor | Standard | Standard | Standard | Standard | Standard | Standard |
Wall Insulation | Standard | Standard | Standard | Standard | Standard | Standard |
Roof Insulation | Standard | Standard | Standard | Standard | Standard | Standard |
All dimensions given in mm) | All dimensions given in mm) | All dimensions given in mm) | All dimensions given in mm) | All dimensions given in mm) | All dimensions given in mm) | All dimensions given in mm) |
TRANSPORT & HANDLING
It is extremely important that the following points are taken into consideration before delivery can be effected:
- Site should be level and compacted. It should not slope more than 200 mm over the length and 100 mm over the width of the unit.
- Site must be accessible for an abnormally large load. All trees and/or other obstacles that may be in the way must be removed beforehand to allow easy access.
- Gates into property must be a minimum of 4 m wide, and truck must have a straight run-up of at least 25 m, to allow bigger units (9 m and upwards) to be offloaded into position, and allow trucks to drive out from under unit after having lifted it.
- Unit will be dropped onto trestles and levelled in order to allow doors to open freely. Final levelling must be done by client unless siting is done and charged for by Ufudu.
- A site inspection prior to delivery can be arranged.
- All equipment used for loading and off-loading of units is certified and load tested.